Mobile coating industry

Mobile coating industry: Mobile coating industry: some entities in the coating plant, such as: spray chamber, polishing chamber, and gumming chamber, need humidifying sets with temperature between 40 ~ 80 % RH in different seasons to avoid static. Static removal can prevent fire accident caused by volatile gas, dust on the surface and create good air condition for spray treatment and improve mobile equipment quality.

Recommended humidifying products:

Central air conditioning set

Yes

No

Vapor source

(Winter humidifying)Yes

No

/

Eligible humidifier type

Dry vapor humidifier, vapor fast diffusing humidifier

High pressure light fog humidifier, wet film humidifier, fog spraying

High pressure light fog humidifier, air and water mixing humidifier

Suitable products

SQ series

SQK series

SWB system

SM system

SWP system

SKK system

SWB system


Tobacco industry

Tobacco industry: Tobacco industry: cigarette production has strict requirement to environment and humidity during each procedure from tobacco storage, selecting, re-drying, throwing, to spinning, with relative humidity between 65 ~ 70 % RH. The higher temperature is, the more moisture tobacco contains. In this way, it can enhance tobacco's mechanical strength, reduce broken rate of tobacco leaf and shred, and finally improve finishing rate and quality.

Recommended humidifying products:

Central air conditioning set

Yes

No

Vapor source

Yes

No

 

Eligible humidifier type

Dry vapor humidifier

High pressure light fog, air and water mixing

Centrifugal humidifier, air and water humidifier, high pressure light fog humidifier

Suitable products (system and mode)

SQ series

SWV system

SKK system

SLB-8.0 SKK system, SWV system

Printing industry

Printing industry: Printing industry: quality is the key to printing. To acquire higher printing quality needs not only good printing equipment, material and technology, but also a good environment with humidity between 55 ~ 65 % RH. This can avoid paper distortion and colorful overprint misplacement. The static can cause dust absorption on the surface and influence the quality and can also cause fire by evaporated gas. The removal of static can ensure safety, improve printing efficiency and quality.

Recommended humidifying products:

air conditioning set

Yes

No

Vapor source

Yes

No

No

Eligible humidifier type

Dry vapor humidifier

High pressure light fog humidifying, air and water mixing

Centrifugal, air and water mixing and high pressure light fog

Suitable products

SQ series

SWB system, SKK

SLB-8.0, SKK, SWB system

Textile industry

Textile industry: Textile industry: the relative humidity has big influence on fiber yarn and can be found in moisture regain, strength, elongation, and pliability. The relative humidity should be between 70 ~ 80 % RH, under which the yarn strength can be increased, breakage reduced, the hair flying lessened, and static removed. It can also guarantee stretching, carding and textile and improve productivity and quality.

Recommended humidifying products:

Central air conditioning set

Yes

No

Vapor source

Yes

No

No

Eligible humidifier type

Dry vapor humidifier

Wet film cycling water and spraying system

Centrifugal, air and water mixing, high pressure light fog

Suitable products

SQ series, SQK

SMXH 、 SP

SLB-8.0, SKK, SWB system

Telecommunication industry

Telecommunication industry: Telecommunication industry: SPC exchanger is a very important part of public network, as well as the core and center of special communication net. The temperature is very important for equipment room. Generally speaking, the relative temperature should be between 40 ~ 60 % RH since the dry air can cause static, which will lead to puncture of integrated circuit plate threaten exchanger.

Recommended humidifying products:

air conditioning set

Yes

No

Eligible humidifier type

Electrode humidifier
Electric heating humidifier

Wet film cabinet humidifier (for equipment room only)

Suitable products

SD series, SRD series, system

SMG series

Refrigerating and fresh keeping industry

Refrigerating and fresh keeping industry: Refrigerating and fresh keeping industry: with the improvement of life quality, people are proposing higher requirement to the storage of fruits, vegetables and flowers. And that means temperature and humidity in warehouse should be controlled strictly. If humidity is not enough, fruits and vegetables will become dry, so the relative humidity should be between 85 ~ 95 % RH.

Recommended humidifying products:

Refrigerating series

Low temperature cold storage

High temperature cold storage (air-conditioning storage)

Eligible humidifier type

Centrifugal humidifier for low temperature cold storage, centrifugal-type, water and air mixing type

Centrifugal humidifier for low temperature cold storage, centrifugal-type, water and air mixing type, high pressure light fog humidifier.

Suitable products

SLB-8.0L, SLB-3.0L, SKK, SLB series, SWB system

SLB-8.0L, SLB series, SWB system

Top hotels, office building and villa

Top hotels, office building and villa: Top hotels, office building and villa: humidifying is to provide a comfortable living and working environment for people. The dry air is bad for health, especially in winter in north. The best living and working condition is between 20 ~ 26℃(temperature)and 40 ~ 60 % rh(humidity). Therefore, the static can be avoided.

Recommended humidifying products:

Construction type

Top hotels, office building, villa

Central air conditioning set

Yes

 

No

Vapor source

Yes

No

No

eligible humidifying tyes

Dry vapor humidifier
Fast-absorbing dry vapor

Double evaporation, wet film, high pressure light fog, electrode, electronic heating, high pressure spraying

Fan coil, family air-conditioner, PTC electronic heating

Suitable products

SQK series

SYS/L series, SRD series, SMPA series

SMF series

Electron industry

Electron industry: Electron industry: at present, the domestic electron plant has higher standard. In order to ensure product quality, the temperature and humidity must be controlled strictly. Special attention should be paid to humidity since static comes from dry air and it will break CMOS integrated circuit (note: experiment shows that static pressure is 10000V when humidity is 20% RH; and static pressure is 20000V when humidity is between 40 ~ 60%RH ). Besides, the over dry air can make the dust fly and cause respiratory disease, therefore, affect the health and working efficient. Generally speaking, electron factory shall control temperature at about 22 ℃ and humidity in 40 ~ 60%RH, in which people feel comfortable and static doesn't exist

Recommended products:

Central air-conditioning set

Yes

Vapor source

Yes

No

Eligible humidifiers

Dry vapor humidifier, Vapor to vapor humidifier

High pressure light fog humidifier,electrode, electric heating

Applied products

SQ series, SQK, STS

SWB series, SD, SRD

HQ:No.2, Bei Yi Tiao, Zhongguancun, Haidian District, Beijing
Sales:No.1, Shangdi Si Jie, Haidian District, Beijing 
P.C.:100085
Website:http://www.bj-stand.com
Tel:+86-10 -+86-10-010-62963366 62968335/36/37/38/39
E-mail:zhoujun@bj-stand.com
京ICP备05078366号
Powered by www.ce.net.cn

WEBPAGE COPYRIGHT (C) 2008 WWW.STAND.COM.CN